Annex G, Articles 90, 100 and 110 |
|
|
2 | (30) |
|
Annex G Administration and Enforcement |
|
|
4 | (1) |
|
90.2(B)(4) and (5) FPN Not Covered |
|
|
5 | (2) |
|
90.5(C) Explanatory Material |
|
|
7 | (1) |
|
Article 100 Bonding Jumper, System |
|
|
8 | (1) |
|
Article 100 Coordination (Selective) |
|
|
9 | (1) |
|
|
10 | (1) |
|
Article 100 Dwelling Unit |
|
|
11 | (2) |
|
Article 100 Grounded, Solidly |
|
|
13 | (1) |
|
Article 100 Grounding Electrode |
|
|
14 | (1) |
|
Article 100 Grounding Electrode Conductor |
|
|
15 | (1) |
|
|
16 | (1) |
|
|
17 | (1) |
|
Article 100 Handhole Enclosure |
|
|
18 | (1) |
|
Article 100 Qualified Person |
|
|
19 | (2) |
|
Article 100 Separately Derived System |
|
|
21 | (1) |
|
Article 100 Supplementary Overcurrent Protective Device |
|
|
22 | (1) |
|
110.12 Mechanical Execution of Work |
|
|
23 | (1) |
|
|
24 | (1) |
|
|
25 | (2) |
|
110.26(A)(1) Depth of Working Space |
|
|
27 | (2) |
|
110.26(C)(2) Large Equipment |
|
|
29 | (2) |
|
Article 110, PART V Manholes and Other Electric Enclosures Intended for Personnel Entry, All Voltages |
|
|
31 | (1) |
|
Wiring and Protection, Articles 200--285 |
|
|
32 | (112) |
|
200.6(B) Sizes Larger Than 6 AWG |
|
|
36 | (1) |
|
200.6(D) Grounded Conductors of Different Systems |
|
|
37 | (1) |
|
Articles 210 & 220 Guest Rooms and Guest Suites |
|
|
38 | (1) |
|
210.4(A), (B), and (D) Multiwire Branch Circuits |
|
|
39 | (3) |
|
210.5(C) Ungrounded Conductors |
|
|
42 | (2) |
|
210.8(A)(7) GFCI Protection, Dwelling Units |
|
|
44 | (1) |
|
210.8(B)(2) GFCI Protection, Other Than Dwelling Units |
|
|
45 | (2) |
|
210.8(B)(4) GFCI Protection, Other Than Dwelling Units |
|
|
47 | (2) |
|
210.8(B)(5) GFCI Protection, Other Than Dwelling Units |
|
|
49 | (1) |
|
|
50 | (2) |
|
210.12(B) and Exception Arc-Fault Circuit-Interrupter Protection in Dwelling Unit Bedrooms |
|
|
52 | (2) |
|
210.18 Guest Rooms and Guest Suites |
|
|
54 | (1) |
|
210.52(B)(1) Small Appliances, Receptacle Outlets Served |
|
|
55 | (1) |
|
210.52(C)(1) Exception and (2) Countertops, Wall Counter Spaces, and Island Counter Spaces |
|
|
56 | (2) |
|
210.52(D) and Exception Dwelling Unit Bathrooms |
|
|
58 | (1) |
|
210.52(E) Dwelling Unit Outdoor Receptacle Outlets |
|
|
59 | (1) |
|
210.60(A) Guest Rooms or Guest Suites, General |
|
|
60 | (2) |
|
210.63 Exception Heating, Air-Conditioning, and Refrigeration Equipment Outlet |
|
|
62 | (1) |
|
210.70(B) Lighting Outlets Required, Guest Rooms or Guest Suites |
|
|
63 | (2) |
|
215.2(A)(1) Minimum Rating and Size, Feeders Not More Than 600 Volts, General |
|
|
65 | (2) |
|
215.12 Identification of Feeders |
|
|
67 | (1) |
|
Article 220 Branch-Circuit, Feeder, and Service Calculations |
|
|
68 | (2) |
|
220.82(C) and Example D2(c) Dwelling Unit, Heating and Air-Conditioning Load |
|
|
70 | (2) |
|
|
72 | (1) |
|
225.22 Raceways on Exterior Surfaces of Buildings or Other Structures |
|
|
73 | (1) |
|
225.30 Number of Supplies, Special Conditions |
|
|
74 | (2) |
|
230.2(A)(6) Number of Services, Special Conditions |
|
|
76 | (2) |
|
230.40 Exception No. 1 Number of Service-Entrance Conductor Sets |
|
|
78 | (2) |
|
230.71(A) Maximum Number of Disconnects, General |
|
|
80 | (2) |
|
230.72(B) Additional Service Disconnecting Means |
|
|
82 | (2) |
|
230.82(2) and (3) Equipment Connected to the Supply Side of Service Disconnect |
|
|
84 | (2) |
|
230.82(8) Equipment Connected to the Supply Side of Service Disconnect |
|
|
86 | (1) |
|
240.2 Supervised Industrial Installation |
|
|
87 | (1) |
|
240.20(B)(1), (2), and (3) Circuit Breaker as Overcurrent Device |
|
|
88 | (1) |
|
|
89 | (1) |
|
240.21(B)(3)(2) Taps Supplying a Transformer [Primary Plus Secondary Not Over 7.5 m (25 ft) Long] |
|
|
90 | (2) |
|
240.21(C) Transformer Secondary Conductors |
|
|
92 | (2) |
|
240.21(C)(2)(1) Transformer Secondary Conductors Not Over 3 m (10 ft) Long |
|
|
94 | (2) |
|
240.24 Location in or on Premises, Accessibility |
|
|
96 | (1) |
|
240.60(D) (New) Renewable Fuses |
|
|
97 | (1) |
|
|
98 | (2) |
|
Article 250 Grounding and Bonding |
|
|
100 | (1) |
|
250.2 Effective Ground-Fault Current Path |
|
|
101 | (1) |
|
250.8 Connection of Grounding and Bonding Equipment |
|
|
102 | (1) |
|
250.21 Alternating-Current Systems of 50 Volts to 1000 Volts Not Required to Be Grounded |
|
|
103 | (2) |
|
250.28 Main Bonding Jumper and System Bonding Jumper |
|
|
105 | (2) |
|
250.30 Grounding Separately Derived Alternating-Current Systems |
|
|
107 | (6) |
|
250.32 Buildings or Structures Supplied by Feeder(s) or Branch Circuit(s) |
|
|
113 | (2) |
|
250.50 Grounding Electrode System |
|
|
115 | (2) |
|
250.52(A)(2) Metal Frame of the Building or Structure |
|
|
117 | (2) |
|
250.64(C) Grounding Electrode Conductor Installation, Continuous |
|
|
119 | (2) |
|
250.64(D) Grounding Electrode Conductor Taps |
|
|
121 | (2) |
|
250.64(E) Enclosures for Grounding Electrode Conductors |
|
|
123 | (2) |
|
250.68(A) Exception No. 2 (New) Grounding Electrode Conductor and Bonding Jumper Connection to Grounding Electrodes, Accessibility |
|
|
125 | (2) |
|
250.100 Bonding in Hazardous (Classified) Locations |
|
|
127 | (1) |
|
250.118(5)(d) and (6)(e) Types of Equipment Grounding Conductors, Flexible Metal Conduit and Liquidtight Flexible Metal Conduit |
|
|
128 | (2) |
|
250.119 Identification of Equipment Grounding Conductors |
|
|
130 | (2) |
|
250.122(G) Size of Equipment Grounding Conductors, Feeder Taps |
|
|
132 | (2) |
|
250.142(B) Exception No. 2 Use of Grounded Circuit Conductor for Grounding Equipment |
|
|
134 | (1) |
|
250.146(A) Connecting Receptacle Grounding Terminal to Box, Surface Mounted Box |
|
|
135 | (1) |
|
250.148 Continuity and Attachment of Equipment Grounding Conductors to Boxes |
|
|
136 | (2) |
|
250.184 Part X Grounding of Systems and Circuits of 1 kV and Over (High Voltage), Solidly Grounded Neutral Systems |
|
|
138 | (3) |
|
280.4(A) Surge Arrester Selection, Circuits of Less Than 1000 Volts |
|
|
141 | (2) |
|
285.3 Transient Voltage Surge Suppressor, Uses Not Permitted |
|
|
143 | (1) |
|
Wiring Methods and Materials, Articles 300--398 |
|
|
144 | (60) |
|
300.4(A)(1) Exception No. 2 (New) and 300.4(A)(2) Cables and Raceways Through Wood Members, Bored Holes and Notches in Wood |
|
|
146 | (2) |
|
300.4(D) Cables and Raceways Parallel to Framing Members and Furring Strips |
|
|
148 | (1) |
|
300.5(B) Underground Installations, Listing |
|
|
149 | (1) |
|
300.6 Protection Against Corrosion and Deterioration |
|
|
150 | (2) |
|
300.11(A)(1) Securing and Supporting, Fire-Rated Assemblies |
|
|
152 | (1) |
|
300.15(L) Manholes and Handholes |
|
|
153 | (2) |
|
300.22(B) Ducts or Plenums Used for Environmental Air |
|
|
155 | (1) |
|
310.4 Conductors in Parallel |
|
|
156 | (3) |
|
310.5 Minimum Size of Conductors |
|
|
159 | (1) |
|
310.6, Exception Shielding |
|
|
160 | (2) |
|
310.8(D) Locations Exposed to Direct Sunlight |
|
|
162 | (1) |
|
310.10, FPN No. 2 (New) Temperature Limitation of Conductors |
|
|
163 | (2) |
|
310.15(B)(2)(a) and FPN No. 2 Adjustment Factors, More Than Three Current-Carrying Conductors in a Raceway or Cable |
|
|
165 | (2) |
|
312.2(A) Damp and Wet Locations |
|
|
167 | (2) |
|
312.4 (New) Repairing Plaster and Drywall or Plasterboard |
|
|
169 | (1) |
|
Article 314 Outlet, Device, Pull, and Junction Boxes; Conduit Bodies; Fittings and Handhole Enclosures |
|
|
170 | (2) |
|
314.16(B)(1) Box Fill Calculations, Conductor Fill |
|
|
172 | (2) |
|
314.23(B)(1) Nails and Screws |
|
|
174 | (1) |
|
314.27(D) Boxes at Ceiling-Suspended (Paddle) Fan Outlets |
|
|
175 | (1) |
|
314.30 (New) Handhole Enclosures |
|
|
176 | (2) |
|
320.10 and 320.12 Armored Cable: Type AC, Uses Permitted and Uses Not Permitted |
|
|
178 | (2) |
|
320.30 Type AC Cable, Securing and Supporting |
|
|
180 | (2) |
|
320.80(A) Type AC Cable, Ampacity, Thermal Insulation |
|
|
182 | (1) |
|
334.12(A) Type NM Cable, Uses Not Permitted |
|
|
183 | (2) |
|
334.15(B) Type NM Cable, Protection From Physical Damage |
|
|
185 | (1) |
|
334.30 Type NM Cable, Securing and Supporting |
|
|
186 | (1) |
|
334.80 Type NM Cable, Ampacity |
|
|
187 | (2) |
|
342.22 Intermediate Metal Conduit, Number of Conductors |
|
|
189 | (2) |
|
344.24 Rigid Metal Conduit, Bends---How Made |
|
|
191 | (1) |
|
348.30(A) Exception No. 2 Flexible Metal Conduit, Securely Fastened |
|
|
192 | (2) |
|
352.12(E) Rigid Nonmetallic Conduit, Uses Not Permitted, Insulation Temperature Limitations |
|
|
194 | (2) |
|
Article 353 High Density Polyethylene Conduit: Type HDPE Conduit |
|
|
196 | (2) |
|
372.17 Cellular Concrete Floor Raceways, Ampacity of Conductors |
|
|
198 | (1) |
|
376.23(A) and (B) Metal Wireways, Insulated Conductors |
|
|
199 | (2) |
|
378.23(A) and (B) Nonmetallic Wireways, Insulated Conductors |
|
|
201 | (2) |
|
392.4 Cable Trays, Uses Not Permitted |
|
|
203 | (1) |
|
Equipment for General Use, Articles 400-490 |
|
|
204 | (60) |
|
400.5 Ampacities for Flexible Cords and Cables |
|
|
206 | (2) |
|
400.8(7) Flexible Cord, Uses Not Permitted |
|
|
208 | (1) |
|
404.9(B) Exception Provisions for General-Use Snap Switches, Grounding |
|
|
209 | (2) |
|
406.4(A) and (B) Receptacle Mounting |
|
|
211 | (1) |
|
406.4(D) Exception Nos. 1 and 2 Position of Receptacle Faces |
|
|
212 | (2) |
|
406.6(A), (B), and (D) Attachment Plugs, Cord Connectors, and Flanged Surface Devices |
|
|
214 | (1) |
|
406.8(B)(1), (2), (C), and (E) Receptacles in Wet Locations |
|
|
215 | (2) |
|
408.4 Circuit Directory or Circuit Identification |
|
|
217 | (1) |
|
408.7 Switchboards and Panelboards, Unused Openings |
|
|
218 | (1) |
|
Article 409 Industrial Control Panels |
|
|
219 | (2) |
|
410.4(D) Bathtub and Shower Areas |
|
|
221 | (2) |
|
410.4(E) Luminaires (Fixtures) in Indoor Sports, Mixed-Use, and All-Purpose Facilities |
|
|
223 | (1) |
|
410.18(B) Exception No. 2 Exposed Luminaire (Fixture) Parts Made of Insulating Materal |
|
|
224 | (2) |
|
410.73(F)(5) High-Intensity Discharge Luminaires (Fixtures), Metal Halide Lamp Containment |
|
|
226 | (2) |
|
410.73(G) High-Intensity Discharge Luminaires (Fixtures), Disconnecting Means |
|
|
228 | (3) |
|
422.13 Storage-Type Water Heaters |
|
|
231 | (2) |
|
422.16(B)(4) Flexible Cords for Specific Appliances, Range Hoods |
|
|
233 | (2) |
|
422.31(B) Disconnection, Appliances Rated Over 300-Volt-Amperes or 1/8 Horsepower |
|
|
235 | (2) |
|
422.51 Cord-and-Plug-Connected Vending Machines |
|
|
237 | (2) |
|
424.3(B) Fixed Electric Space-Heating Equipment, Branch-Circuit Sizing |
|
|
239 | (2) |
|
430.6(A)(1), Tables 430.248, 430.249, 430.250 Ampacity and Motor Rating Determinations, General Motor Applications, Table Values |
|
|
241 | (2) |
|
430.8, Exceptions Marking on Controllers |
|
|
243 | (2) |
|
430.32(A) Continuous-Duty Motors, More Than 1 Horsepower |
|
|
245 | (1) |
|
430.102(B), Exception Disconnecting Means, Motor |
|
|
246 | (2) |
|
430.109(A)(6) Manual Motor Controller |
|
|
248 | (1) |
|
430.2 and 430.109(A)(7) System Isolation Equipment |
|
|
249 | (3) |
|
430.2 and Article 430 Part X Adjustable Speed Drives |
|
|
252 | (2) |
|
440.4(B), Exception Multimotor and Combination-Load Equipment |
|
|
254 | (2) |
|
440.14 Exception No. 1 Disconnecting Means, Location |
|
|
256 | (2) |
|
440.32 Single Motor Compressor |
|
|
258 | (1) |
|
|
259 | (1) |
|
445.18 Disconnecting Means Required for Generators |
|
|
260 | (1) |
|
450.5 Grounding Autotransformers |
|
|
261 | (1) |
|
490.46 Metal-Enclosed and Metal-Clad Service Equipment |
|
|
262 | (2) |
|
Special Occupancies, Articles 500--590 |
|
|
264 | (54) |
|
500.2 Purged and Pressurized |
|
|
266 | (1) |
|
500.7(K) Combustible Gas Detection System |
|
|
267 | (2) |
|
501.10(B)(6) Wiring Methods, Class I, Division 2 Areas |
|
|
269 | (1) |
|
501.15(B)(2), and Exception No.2 Conduit Seals, Class I, Division 2 Boundary |
|
|
270 | (2) |
|
501.15(F)(3) Sealing and Drainage, Canned Pumps, Process, or Service Connections, etc. |
|
|
272 | (2) |
|
501.25, 502.25, 503.25, 505.19 Uninsulated Exposed Parts, Class I, Divisions 1 & 2; Class II, Divisions 1 & 2; Class III, Divisions 1 & 2 |
|
|
274 | (2) |
|
502.15(4) Sealing, Class II, Divisions 1 and 2 |
|
|
276 | (2) |
|
502.10(A)(2) Class II, Division 1, Flexible Connections |
|
|
278 | (2) |
|
503.10(A)(3) Class III Wiring Methods, Nonincendive Field Wiring |
|
|
280 | (1) |
|
Article 506 Zone 20, 21, and 22 Locations for Combustible Dusts, Fibers, and Flyings |
|
|
281 | (2) |
|
511.3 Commercial Garages, Repair and Storage, Classification of Locations |
|
|
283 | (2) |
|
511.4 Commercial Repair Garage, Wiring and Equipment in Class I Locations |
|
|
285 | (1) |
|
513.12 Aircraft Hangars, Ground-Fault Circuit-Interrupter Protection for Personnel |
|
|
286 | (1) |
|
514.2, Table 514.3(B)(1) Motor Fuel Dispensing Facility, Table 514.3(B)(1) Class I Locations---Motor Fuel Dispensing Facilities |
|
|
287 | (2) |
|
514.8 Motor Fuel Dispensing Facilities, Underground Wiring |
|
|
289 | (2) |
|
516.3 Classification of Locations |
|
|
291 | (3) |
|
517.13(A), (B) Grounding of Receptacles and Fixed Electric Equipment in Patient Care Areas |
|
|
294 | (2) |
|
517.17(A) Health Care Facilities, Ground-Fault Protection |
|
|
296 | (2) |
|
517.30(C)(3) Essential Electrical Systems for Hospitals, Mechanical Protection of the Emergency System |
|
|
298 | (2) |
|
Article 518, 518.2 Assembly Occupancies |
|
|
300 | (2) |
|
518.4(C) Assembly Occupancies, Wiring Methods, Spaces with Finish Rating |
|
|
302 | (2) |
|
525.10, 525.11 Services, Multiple Sources of Supply |
|
|
304 | (2) |
|
525.23 Ground-Fault Circuit-Interrupter (GFCI) Protection |
|
|
306 | (2) |
|
547.5(G) Agricultural Buildings, Receptacles |
|
|
308 | (1) |
|
547.9 Electric Supply to Building(s) or Structure(s) From a Distribution Point |
|
|
309 | (2) |
|
547.10 Equipotential Plane Requirements for Agricultural Buildings |
|
|
311 | (2) |
|
555.21 and 555.22 Motor Fuel Dispensing Stations, Repair Facilities |
|
|
313 | (2) |
|
Article 590 Temporary Installations |
|
|
315 | (1) |
|
590.4(B) and (C) Temporary Installations, Feeders and Branch Circuits |
|
|
316 | (2) |
|
Special Equipment, Articles 600--695 |
|
|
318 | (48) |
|
600.2, 600.8, 600.24 Section Sign, Enclosures, Class 2 Power Sources |
|
|
320 | (2) |
|
604.6(E) Manufactured Wiring Systems, Securing and Supporting |
|
|
322 | (1) |
|
605.6, 605.7 Office Furnishings, Fixed-Type Partitions and Freestanding-Type Partitions |
|
|
323 | (2) |
|
610.61 Cranes and Hoists, Grounding |
|
|
325 | (1) |
|
620.22(A) Elevators, Etc., Car Light Source |
|
|
326 | (1) |
|
|
327 | (1) |
|
625.25, 625.26 Loss of Primary Source and Interactive Systems |
|
|
328 | (1) |
|
640.6 Mechanical Execution of Work |
|
|
329 | (1) |
|
FPN to 670.1 Industrial Machinery, Scope |
|
|
330 | (2) |
|
680.8 Swimming Pools and Similar, Overhead Conductor Clearances |
|
|
332 | (1) |
|
680.12 Swimming Pools and Similar, Maintenance Disconnecting Means |
|
|
333 | (1) |
|
680.21(A)(4) Swimming Pools and Similar, One-Family Dwellings |
|
|
334 | (2) |
|
680.23(B)(2) Swimming Pools and Similar, Wiring Extending Directly to the Forming Shell |
|
|
336 | (1) |
|
680.23(B)(6) Wet-Niche Luminaires (Fixtures), Servicing |
|
|
337 | (1) |
|
680.26 Swimming Pools and Similar, Equipotential Bonding |
|
|
338 | (4) |
|
680.32, 680.34 Storable Pools, Ground-Fault Circuit Interrupters Required, Receptacle Locations |
|
|
342 | (1) |
|
680.51(A) Fountains, Ground-Fault Circuit Interrupter |
|
|
343 | (1) |
|
680.74 Hydromassage Bathtubs, Bonding |
|
|
344 | (2) |
|
Article 682 Natural and Artificially Made Bodies of Water |
|
|
346 | (4) |
|
685.1 Integrated Electrical Systems, Scope |
|
|
350 | (2) |
|
690.2, 690.31(E) Building Integrated Photovoltaics, Wiring Methods Permitted |
|
|
352 | (2) |
|
690.14(D) Utility Interactive-Inverters Mounted in Not-Readily Accessible Locations |
|
|
354 | (2) |
|
690.47(C) Photovoltaic Systems With Alternating-Current and Direct-Current Grounding Requirements |
|
|
356 | (2) |
|
692.1 Fuel Cell Systems, Scope |
|
|
358 | (1) |
|
695.3(A)(1) Electric Utility Service Connection for Fire Pumps |
|
|
359 | (1) |
|
695.4(B)(1) and (B)(2)(3) Supervised Connection, Overcurrent Device Selection, Disconnecting Means |
|
|
360 | (2) |
|
695.5(B) and (C)(2) Overcurrent Protection for Transformers, Overcurrent Protection for Feeders |
|
|
362 | (2) |
|
695.6(C)(2), (D), (E), and (H) Power Wiring for Fire Pumps, Overcurrent Protection, Pump Wiring, and Ground-Fault Protection Prohibition |
|
|
364 | (2) |
|
Special Conditions, Articles 700--780 |
|
|
366 | (26) |
|
700.5(B) Emergency Systems, Selective Load Pickup, Load Shedding, and Peak Load Shaving |
|
|
368 | (2) |
|
700.12(B)(6) Emergency System, Outdoor Generator Sets |
|
|
370 | (1) |
|
700.12(D) Emergency Systems, Separate Service |
|
|
371 | (2) |
|
700.12(E) Emergency Systems, Fuel Cell System |
|
|
373 | (2) |
|
700.27, 701.18 Emergency Systems and Legally Required Standby Systems, Coordination |
|
|
375 | (2) |
|
702.6 Exception Optional Standby Systems, Transfer Equipment |
|
|
377 | (2) |
|
702.7 Exception Optional Standby Systems, Signals |
|
|
379 | (1) |
|
702.11 Optional Standby Systems, Sources of Power |
|
|
380 | (1) |
|
725.3(B) Spread of Fire or Products of Combustion |
|
|
381 | (1) |
|
725.3(C) Ducts, Plenums, and Other Air-Handling Spaces |
|
|
382 | (1) |
|
|
383 | (1) |
|
725.56(F) Class 2 or Class 3 Conductors or Cables and Audio System Circuits |
|
|
384 | (1) |
|
725.61(D)(2) Intrinsically Safe Circuits and Nonincendive Field Wiring |
|
|
385 | (1) |
|
760.21 Non-Power-Limited Fire Alarm Circuit Power Source Requirements |
|
|
386 | (2) |
|
760.41 Power Sources for Power-Limited Fire Alarm Circuits |
|
|
388 | (2) |
|
760.61(A), 760.61(B), and 760.61(C) Applications of Listed Power-Limited Fire Alarm Cables |
|
|
390 | (2) |
|
Communication Systems, Articles 800--830; and Annexes |
|
|
392 | (12) |
|
800.2 Communications Circuit Integrity (CI) Cable |
|
|
394 | (1) |
|
800.100(A)(4) FPN Primary Protector Grounding Conductor |
|
|
395 | (1) |
|
800.113 Installation and Marking of Communications Wires and Cables |
|
|
396 | (2) |
|
Annex D, Example D3(a) D3(a) Industrial Feeders in a Common Raceway |
|
|
398 | (5) |
|
Annex E Types of Construction |
|
|
403 | (1) |
Index |
|
404 | |